Electro Mechanical Industries Switchboard VLB347 | 3000 Amp Main Fusible | 480Y/277V 3-Phase 4-Wire | NEMA 3R R&G

Electro Mechanical Industries Switchboard; 3000 amp main fusible, 480Y/277 volt, 3 phase, 4 wire, NEMA 3R outdoor rated. With 800 amp main fusible switch- cat # VLB347. Reconditioned & guaranteed with a one-year warranty.
SKU: M249
Contact us for pricing:

Electro-Mechanical Industries BPS Switchboard VLB3412 | 3000 Amp Main Fusible | 480Y/277V 3-Phase 4-Wire | NEMA 1 R&G

Electro-Mechanical Industries; 3000 amp main fusible switch- cat # VLB3412, 480/277 volt, three phase, four wire, NEMA 1 indoor. Reconditioned & guaranteed with a one year warranty.
SKU: M252
Contact us for pricing:

Electro-Mechanical Industries SACE E2.2H-A Switchboard | 4000 Amp Main Lug Only | 208Y/120V 3-Phase 4-Wire | NEMA 1 R&G

Electro-Mechanical Industries SACE E2.2H-A Switchboard; 4000 amp main lug only, 208Y/120 volt, 3 phase, 4 wire, NEMA 1 indoor. With (2) 1600 amp distribution breakers-arc flash reduction. Reconditioned & guaranteed with a one-year warranty.
SKU: M559
Contact us for pricing:

Electro-Mechanical Industries Switchboard SBS612 | 1200 Amp Main Breaker | 480Y/277V 3-Phase 4-Wire | NEMA 1 R&G

Electro-Mechanical Industries Switchboard; 1200 amp main breaker- cat # SBS6123WEA, 480Y/277 volt, 3 phase, 4 wire, ground fault, arc flash reduction, NEMA 1 indoor rated. Reconditioned & guaranteed with a one-year warranty.
SKU: M747
Contact us for pricing:

General Electric AV-Line Switchboard | 2000 Amp Main Lug Only | 480V 3-Phase 3-Wire | NEMA 3R R&G

General Electric AV-Line Switchboard Main Lug Only; 2000 amp, 480 volt, 3 phase, 3 wire, NEMA 3R outdoor rated. With (2) power break I distribution panels. Reconditioned & guaranteed with a one-year warranty.
SKU: M641
Contact us for pricing:

General Electric AV-Line Switchboard CBC-2033-B | 2000 Amp Main Fusible | 480Y/277V 3-Phase 4-Wire | NEMA 1 R&G

General Electric AV-Line Switchboard; 2000 amp main fusible pringle switch- cat # CBC-2033-B, 480Y/277 volt, three phase, four wire, ground fault, shunt trip, NEMA 1 indoor. With (1) QMR THFP fusible switch panel. Reconditioned & guaranteed with a one year warranty.
SKU: M271
Contact us for pricing:

General Electric AV-Line Switchboard QA-3033-CBC | 3000 Amp Main-Tie-Main | 480Y/277V 3-Phase 4-Wire | NEMA 1 R&G

General Electric AV-Line Switchboard; 3000 amp main-tie-main- cat # QA-3033-CBC, 480Y/277 volt, three phase, four wire, ground fault, NEMA 1 indoor. With (7) QA fusible switch distribution panels. Reconditioned and guaranteed with a one-year warranty.
SKU: M478
Contact us for pricing:

General Electric AV-Line Switchboard SSD20B220 | 2000 Amp Main Breaker | 480V 3-Phase 4-Wire | NEMA 1 R&G

General Electric AV-Line Switchboard; 2000 amp Power Break II main breaker- cat # SSD20B220, 480 volt, 3 phase, 4 wire, ground fault, NEMA 1 indoor. With (1) section of Power Break II distribution breakers. Reconditioned & guaranteed with a one year warranty.
SKU: M567
Contact us for pricing:

General Electric AV-Line Switchboard TC4040SSHE1 | 4000 Amp Main Breaker | 480Y/277V 3-Phase 4-Wire | NEMA 1 R&G

General Electric AV-Line Switchboard; 4000 amp main breaker- cat # TC4040SSHE1, 480Y/277 volt AC, 3 phase, 4 wire, ground fault, NEMA 1 indoor rated. Reconditioned & guaranteed with a one-year warranty.
SKU: M493
Contact us for pricing:

General Electric AV-Line Switchboard TCVVF9640E1 | 4000 Amp Main Breaker | 480Y/277V 3-Phase 4-Wire | NEMA 1 R&G

General Electric AV-Line Switchboard; 4000 amp power break main breaker- cat# TCVVF9640E1, 480Y/277 volt AC, three phase, four-wire, ground fault, NEMA 1 indoor rated. Reconditioned & guaranteed with a one year warranty.
SKU: M514
Contact us for pricing:

General Electric AV-Line Switchboard TCVVF9640E1 | 4000 Amp Main Breaker | 480Y/277V 3-Phase 4-Wire | NEMA 1 R&G

General Electric AV-Line Switchboard; 4000 amp power break main breaker- cat# TCVVF9640E1, 480Y/277 volt AC, three phase, four-wire, ground fault, NEMA 1 indoor rated. Reconditioned & guaranteed with a one year warranty.
SKU: M515
Contact us for pricing:

General Electric AV-Line Switchboard TCVVF9640E1 | 4000 Amp Main Breaker | 480Y/277V 3-Phase 4-Wire | NEMA 1 R&G

General Electric AV-Line Switchboard; 4000 amp power break main breaker- cat# TCVVF9640E1, 480Y/277 volt AC, three phase, four-wire, NEMA 1 indoor rated. Reconditioned & guaranteed with a one year warranty.
SKU: M526
Contact us for pricing:

General Electric AV-Line Switchboard TCVVF9640E1 | 4000 Amp Main Breaker | 480Y/277V 3-Phase 4-Wire | NEMA 1 R&G

General Electric AV-Line Switchboard; 4000 amp power break main breaker- cat# TCVVF9640E1, 480Y/277 volt AC, three phase, four-wire, ground fault, NEMA 1 indoor rated. Reconditioned & guaranteed with a one year warranty.
SKU: M528
Contact us for pricing:

General Electric AV-Line Switchboard THP3030SS | 3000 Amp Main Breaker | 208Y/120V 3-Phase 4-Wire | NEMA 1 R&G

General Electric AV-Line Switchboard; 3000 amp main breaker- cat # THP3030SS, 208Y/120 volt, 3 phase, 4 wire, ground fault, NEMA 1 indoor. With (2) sections of Spectra breaker distribution panels. Reconditioned & guaranteed with a one-year warranty.
SKU: M737
Contact us for pricing:

General Electric AV-Line Switchboard THPMM76E1 | 2000 Amp Main Breaker | 600V DC 2-Wire 2-Pole | NEMA 1 R&G

General Electric AV-Line Switchboard; 2000 amp rated trip, 2500 amp main breaker cat # - THPMMF76E1, 600 volt DC, 120 volt AC, 2 pole. 2 wire, electrically operated (E/O), NEMA 1 indoor. Reconditioned & guaranteed with a one year warranty.
SKU: M247
Contact us for pricing:

General Electric AV-Line Switchboard THPMMF76 | 2000 Amp Main Breaker | 600V 3-Phase 3-Wire | NEMA 1 R&G

General Electric AV-Line Switchboard; 2000 amp main breaker- cat # THPMMF76, 600 volt, 3 phase, 3 wire, NEMA 1 indoor. Reconditioned & guaranteed with a one year warranty.
SKU: M125
Contact us for pricing:

General Electric AV-Line Switchboard THPMMF76E1 | 2500 Amp Main Breaker | 600V DC 2-Wire | NEMA 1 R&G

General Electric AV-Line Switchboard; 2500 amp main breaker-cat # THPMMF76E1, 600 volt DC, two wire, NEMA 1 indoor. Feed-in / feed-out style single section. Reconditioned and guaranteed with a one year warranty.
SKU: M279
Contact us for pricing:

General Electric AV-Line Switchboard THPR3416ET1 | 1600 Amp Main Fusible | 480Y/277V 3-Phase 4-Wire | NEMA 1 R&G

General Electric AV-Line Switchboard; 1600 amp main fusible switch- cat # THPR3416ET1, 480Y/277 volt AC, three pole, three phase, four wire, ground fault, NEMA 1 indoor. With (1) QMR fusible distribution panel. Reconditioned and guaranteed with a one-year warranty.
SKU: M467
Contact us for pricing:

General Electric AV-Line Switchboard THPR3612 | 1200 Amp Main Fusible | 480Y/277V 3-Phase 4-Wire | NEMA 1 R&G

General Electric AV-Line Switchboard; 1200 amp fusible main HPC switch- cat # THPR3612, 480Y/277 volt AC, manually operated (M/O), NEMA 1 indoor. Reconditioned & guaranteed with a one year guaranteed.
SKU: M070
Contact us for pricing:

General Electric AV-Line Switchboard THPR3612B | 1200 amp Main Fusible | 480V 3-Phase 4-Wire | NEMA 1 R&G

General Electric AV-Line Switchboard; 1200 amp main fusible switch-cat # THPR3612B, 480Y/277 volt, three phase, four wire, NEMA 1 indoor. Reconditioned & guaranteed with a one year warranty.
SKU: M082
Contact us for pricing:

Upgrade Low Voltage Switchgear: New, Refurbished, Obsolete

We don’t just sell Low Voltage Switchgear. We provide tailored solutions by understanding your situation as a trusted partner in identifying what you need. Asking questions like:

What are the Voltage Rating Requirements?

Let’s make sure the switchgear's voltage rating matches the requirements of the electrical system it will be installed in. Low voltage switchgear typically operates at voltages up to 1000V AC or 1500V DC. Beyond this, consider Medium Voltage switchgear.

What is the Maximum Current Rating?

It’s important to know the maximum current that the switchgear can handle safely. This should align with the expected load and short-circuit currents in the system.

Where is the Operating Environment?

Evaluate the environmental conditions where the switchgear will be installed, including temperature, humidity, dust, and corrosive elements. Choose switchgear with appropriate ingress protection (IP) ratings and environmental certifications.

What Type of Protection is Needed?

By knowing this, we can decide whether the application requires protection against overload, short circuit, or both. Select switchgear with built-in protection features such as circuit breakers, fuses, or protective relays as needed.

How Much Space Do You Have:

Consider the physical dimensions and layout of the installation site to ensure the switchgear fits properly and allows for future expansion if necessary.

Which Safety Standards Need to Be Met?

Verifying the switchgear complies with relevant safety standards and certifications such as IEC, ANSI, UL, or other local regulations. This way the equipment meets minimum safety requirements and performance standards.

What About Reliability and Durability?

Look for switchgear from reputable manufacturers known for producing reliable and durable equipment. Consider factors such as component quality, design robustness, and maintenance requirements.

Is Remote Monitoring and Control Needed?

If remote monitoring and control are desired, choose switchgear with compatible communication interfaces (such as Modbus, Profibus, or Ethernet) and software capabilities for seamless integration into the overall control system.

Have You Considered Arc Flash Mitigation?

Evaluate the switchgear's ability to minimize the risk and severity of arc flash incidents through design features such as arc-resistant construction, fast fault-clearing times, and proper equipment labeling.

What About Cost and Total Ownership?

Assess the initial purchase cost along with long-term maintenance, operating costs, and potential energy savings. Consider the total cost of ownership over the switchgear's lifecycle to make an informed investment decision.

 

How Can We Help?

Let us help you choose the right Low Voltage Switchgear Solution with confidence. You have customized low voltage switchgear needs? We'll match voltage levels, load capacity, and fault current ratings, to name a few considerations. Your switchgear has special demands, so our solutions balance upfront costs with long-term value, with each unit undergoing testing to lower your total cost over its lifespan.